• 1

    Irving DB, Cook JL, Menz HB: Factors associated with chronic plantar heel pain: a systematic review. .J Sci Med Sport 9::11. ,2006. .

  • 2

    Barrett SL, Jarvis J: Equinus deformity as a factor in forefoot nerve entrapment: treatment with endoscopic gastrocnemius recession. .JAPMA 95::464. ,2005. .

  • 3

    Dananberg HJ, Shearstone J, Guillano M: Manipulation method for the treatment of ankle equinus. .JAPMA 90::385. ,2000. .

  • 4

    Lavery LA, Armstrong DG, Boulton AJ: Ankle equinus deformity and its relationship to high plantar pressure in a large population with diabetes mellitus. .JAPMA 92::479. ,2002. .

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 5

    Armstrong DG, Stacpoole-Shea S, Nguyen H, et al: Lengthening of the Achilles tendon in diabetic patients who are at high risk for ulceration of the foot. .J Bone Joint Surg Am 81::535. ,1999. .

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 6

    Hill RS: Ankle equinus: prevalence and linkage to common foot pathology. .JAPMA 85::295. ,1995. .

  • 7

    Davis JA, Bull RH, Farrelly IH, et al: A home-based exercise programme improves ankle range of motion in long-term venous ulcer patients. .Phlebology 22::86. ,2007. .

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 8

    Sobel E, Caselli MA, Velez Z: Effect of persistent toe walking on ankle equinus: analysis of 60 idiopathic toe walkers. .JAPMA 87::17. ,1997. .

  • 9

    Allington NJ, Leroy N, Doneux C: Ankle joint range of motion measurements in spastic cerebral palsy children: intraobserver and interobserver reliability and reproducibility of goniometry and visual estimation. .J Pediatr Orthop B 11::236. ,2002. .

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 10

    Johnson CH, Christensen JC: Biomechanics of the first ray: part V. The effect of equinus deformity: a 3-dimensional kinematic study on a cadaver model. .J Foot Ankle Surg 44::114. ,2005. .

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 11

    Rome K: Ankle joint dorsiflexion measurement studies: a review of the literature. .JAPMA 86::205. ,1996. .

  • 12

    Brantingham JW, Gilbert JL, Shaik J, et al: Sagittal plane blockage of the foot, ankle and hallux and foot alignment-prevalence and association with low back pain. .J Chirop Med 5::123. ,2006. .

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 13

    Root ML, Orion WP, Weed JH: Normal and Abnormal Function of the Foot, Clinical Biomechanics Corp, Los Angeles. ,1977. .

    • PubMed
    • Export Citation
  • 14

    Lundgren P, Nester C, Liu A, et al: Invasive in vivo measurement of rear-, mid- and forefoot motion during walking. .Gait Posture 28::93. ,2008. .

  • 15

    Gajdosik RL, Bohannon RW: Clinical measurement of range of motion: review of goniometry emphasizing reliability and validity. .Phys Ther 67::1867. ,1987. .

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 16

    Silfverskiold N: Reduction of the uncrossed two-joint muscles of the leg to one-joint muscles in spastic conditions. .Acta Chir Scand 56::315. ,1924. .

  • 17

    Elveru RA, Rothstein JM, Lamb RL: Goniometric reliability in a clinical setting. .Phys Ther 68::672. ,1988. .

  • 18

    Diamond JE, Mueller MJ, Delitto A, et al: Reliability of a diabetic foot evaluation. .Phys Ther 69::797. ,1989. .

  • 19

    Van Gheluwe B, Kirby KA, Roosen P, et al: Reliability and accuracy of biomechanical measurements of the lower extremities. .JAPMA 92::317. ,2002. .

  • 20

    Martin RL, McPoil TG: Reliability of ankle goniometric measurements: a literature review. .JAPMA 95::564. ,2005. .

  • 21

    Evans A, Scutter SD: Sagittal plane range of motion of the pediatric ankle joint: a reliability study. .JAPMA. 96::418. ,2006. .

  • 22

    Wright JG, Feinstein AR: Improving the reliability of orthopaedic measurements. .J Bone Joint Surg Br 74::287. ,1992. .

  • 23

    Moja LP, Telaro E, D’Amico R, et al: Assessment of methodological quality primary studies by systematic reviews: results of the metaquality cross sectional study. .BMJ 330::1053. ,2005. .

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 24

    Whiting P, Rutjes AWS, Reitsma JB, et al: The development of QUADAS: a tool for the quality assessment of studies of diagnostic accuracy included in systematic reviews. .BMC Med Res Method 3::25. ,2003. .

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 25

    Jull A: Evaluation of studies of assessment and screening tools and diagnostic tests. .Evid Based Nurs 5::68. ,2002. .

  • 26

    Bennell K, Talbot R, Wajswelner H, et al: Intra-rater and inter-rater reliability of a weight-bearing lunge measure of ankle dorsiflexion. .Phys Ther 44::175. ,1998. .

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 27

    Digiovanni CW, Holt S, Czerniecki JM, et al: Can the presence of equinus contracture be established by physical exam alone?. J Rehabil Res Dev 38::335. ,2001. .

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 28

    Nitz JC: Low Choy N. The relationship between ankle dorsiflexion range, falls and activity level in women aged 40 to 80 years. .N Z J Physiother 32::121. ,2004. .

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 29

    Baggett BD, Young G: Ankle joint dorsiflexion: establishment of a normal range. .JAPMA 83::251. ,1993. .

  • 30

    Menz HB, Tiedemann A, Kwan MM, et al: Reliability of clinical tests of foot and ankle characteristics in older people. .JAPMA 93::380. ,2003. .

  • 31

    Tesio L, Monzani M, Gatti R, et al: Flexible electrogoniometers: kinesiological advantages with respect to potentiometric goniometers. .Clin Biomech 10::275. ,1995. .

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 32

    Nyanzi CS, Langridge J, Heyworth JR, et al: Randomized controlled study of ultrasound therapy in the management of acute lateral ligament sprains of the ankle joint. .Clin Rehabil 13::16. ,1999. .

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 33

    Backer M, Kofoed H: Passive ankle mobility: clinical measurement compared with radiography. .J Bone Joint Surg Br 71::696. ,1989. .

  • 34

    Woodburn J: Video joint angle position analysis of the subtalar joint position on maximum ankle joint dorsiflexion. .J Br Podiatr Med 46::19. ,1991. .

  • 35

    Moseley AM: The effect of casting combined with stretching on passive ankle dorsiflexion in adults with traumatic head injuries. .Phys Ther 77::982. ,1997. .

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 36

    Muir IW, Chesworth BM, Vandervoort AA: Effect of a static calf-stretching exercise on the resistive torque during passive ankle dorsiflexion in healthy subjects. .J Orthop Sports Phys Ther 29::106. ,1999. .

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 37

    Hume P, Nakamura T, Buford W, et al: Analysis of torque-range-of-motion for the passive viscoelastic properties of the foot/ankle complex. Paper presented at: 18th Annual Conference on Biomedical Engineering Research, Houston, Texas. ,2000. .

    • PubMed
    • Export Citation
  • 38

    Moseley A, Adams R: Measure of passive ankle dorsiflexion: procedure and reliability. .Aust J Physiother 37::175. ,1991. .

  • 39

    Scharfbillig R, Scutter SD: Measurement of foot dorsiflexion: a modified Lidcombe template. .JAPMA 94::573. ,2004. .

  • 40

    Donnery J, Spencer RB: The biplane goniometer: a new device for measurement of ankle dorsiflexion. .JAPMA 78::348. ,1988. .

  • 41

    Moseley AM, Crosbie J, Adams R: Normative data for passive ankle plantarflexion-dorsiflexion flexiblty. .Clin Biomech 16::514. ,2001. .

  • 42

    Assal M, Shofer JB, Rohr E, et al: Assessment of an electronic goniometer designed to measure equinus contracture. .J Rehabil Res Dev 40::235. ,2003. .

  • 43

    Weaver K, Price R, Czerniecki J, et al: Design and validation of an instrument package designed to increase the reliability of ankle range of motion measurements. .J Rehabil Res Dev 38::471. ,2001. .

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 44

    Meyer DC, Werner CM, Wyss T, et al: A mechanical equinometer to measure the range of motion of the ankle joint: interobserver and intraobserver reliability. .Foot Ankle Int 27::202. ,2006. .

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 45

    Wilken J, Saltzman C, Yack H: Reliability and validity of the Iowa ankle range-of-motion device. .J Orthop Sports Phys Ther 34::A17. ,2004. .

  • 46

    Greisberg J, Drake J, Crisco J, et al: The reliability of a new device designed to assess gastrocnemius contracture. .Foot Ankle Int 23::655. ,2002. .

  • 47

    Bobet J, Gossen ER, Stein RB: A comparison of models of force production during stimulated isometric ankle dorsiflexion in humans. .IEEE Trans Neural Syst Rehabil Eng 13::444. ,2005. .

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 48

    Thoms V, Rome K: Effect of subject position on the reliability of measurement of active ankle joint dorsiflexion. .The Foot 7::153. ,1997. .

  • 49

    Tiberio D, Bohannon RW, Zito MA: Effect of subtalar joint position on the measurement of maximum ankle dorsiflexion. .Clin Biomech 4::189. ,1989. .

  • 50

    Mueller MJ, Diamond JE, Delitto A, et al: Insensitivity, limited joint mobility, and plantar ulcers in patients with diabetes mellitus. .Phys Ther 69::453. ,1989. .

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 51

    Pierrynowski MR, Smith SB, Mlynarczyk JH: Proficiency of foot care specialists to place the rearfoot at subtalar neutral. .JAPMA 86::217. ,1996. .

  • 52

    Knight CA, Rutledge CR, Cox ME, et al: Effect of superficial heat, deep heat and active exercise warm up on the extensibility of the plantarflexors. .Phys Ther 81.,2001. .

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 53

    Robertson VJ, Ward AR, Jung P: The effect of heat on tissue extensibility: a comparison of deep and superficial heating. .Arch Phys Med Rehabil 86::819. ,2005. .

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 54

    Lijmer JG, Mol BW, Heisterkamp S, et al: Empirical evidence of design-related bias in studies of diagnostic tests. .JAMA 282::1061. ,1999. .

  • 55

    Currier DP: Elements of Research in Physical Therapy, Ed 2, p 166, Williams & Wilkins, Baltimore. ,1984. .

    • PubMed
    • Export Citation
  • 56

    Kirk J, Miller ML: Reliability and Validity in Qualitative Research, Sage Publications, Beverly Hills. ,1986. .

    • Crossref
    • PubMed
    • Export Citation

Clinical Assessment of Ankle Joint Dorsiflexion

A Review of Measurement Techniques

Alfred Gatt Podiatry Department, Faculty of Health Sciences, University of Malta, Msida, Malta.

Search for other papers by Alfred Gatt in
Current site
Google Scholar
PubMed
Close
 MSc
and
Nachiappan Chockalingam Faculty of Health, Staffordshire University, Stoke-on-Trent, England.

Search for other papers by Nachiappan Chockalingam in
Current site
Google Scholar
PubMed
Close
 PhD

Ankle dorsiflexion measurement is important for clinical and research use. With so much evidence on the unreliability of goniometric measurements, a systematic review was performed to investigate various alternative techniques for measuring ankle dorsiflexion in the nonneurologic patient. All of the major databases were queried electronically to identify studies that used any method of ankle dorsiflexion measurement in the nonneurologic subject. Keywords included ankle dorsiflexion NOT cerebral palsy NOT stroke, the latter to exclude neurologic conditions. In 755 studies that used some form of ankle joint dorsiflexion measurement, ten different techniques were identified that included various apparatuses designed specifically for this purpose. Reliability testing of these techniques involved test-retest trials with small student populations as subjects, which returned high intraclass correlation coefficient scores. However, their methodological quality would have benefitted from the use of an actual patient population and comparison with a reference standard. When validating ankle dorsiflexion measurement techniques, actual patient populations should be used, otherwise papers would score poorly on methodological quality assessment. Standardizing patient position, foot posture, amount of moment applied, and reference landmarks will ensure that various trial results can be compared directly. (J Am Podiatr Med Assoc 101(1): 59–69, 2011)

Corresponding author: Alfred Gatt, MSc, Podiatry Department, Faculty of Health Sciences, University of Malta, Msida, Malta. (E-mail: alfred.gatt@um.edu.mt)
Save