Payne, CB . :The past, present, and future of podiatric biomechanics. .JAPMA 88::53. ,1998. .
Kirby, KA . :Podiatric biomechanics: an integral part of evaluating and treating the athlete. .Med Exerc Nutr Health 2::196. ,1993. .
Root, ML, WP Orien, and JH Weed. :Normal and Abnormal Function of the Foot. ,Clinical Biomechanics Corp. ,Los Angeles. ,1977. .
Menz, HB . :Clinical hindfoot measurement: a critical review of the literature. .The Foot 5::57. ,1995. .
Lee, WE . :Podiatric biomechanics: an historical appraisal and discussion of the Root model as a clinical system of approach in the present context of theoretical uncertainty. .Clin Podiatr Med Surg 18::555. ,2001. .
Harradine, P, L Bevan, and N Carter. :An overview of podiatric biomechanics theory and its relation to selected gait dysfunction. .Physiotherapy 92::122. ,2006. .
Kirby, KA . :Subtalar joint axis location and rotational equilibrium theory of foot function. .JAPMA 91::465. ,2001. .
Gribble, PA, WS Tucker, and PA White. :Time-of-day influences on static and dynamic postural control. .J Athl Train 42::35. ,2007. .
Kirby, KA . :Methods for determination of positional variations in the subtalar joint axis. .JAPMA 77::228. ,1987. .
Ruby, P, ML Hull, KA Kirby, et al. :The effect of lower-limb anatomy on knee loads during seated cycling. .J Biomech 25::1195. ,1992. .
Landis, JR and GG Koch. :The measurement of observer agreement for categorical data. .Biometrics 33::159. ,1977. .
Munro, BH . :Statistical Methods for Health Care Research, ,5th Ed. ,Lippincott Williams & Wilkins. ,Philadelphia. ,2004. .
Mior, SA, M McGregor, and B Schut. :The role of experience in clinical accuracy. .J Manipulative Physiol Ther 13::68. ,1990. .
Exact determination and classification of the spatial position of the subtalar joint axis could be a predictive clinical variable in biomechanical analysis and a valuable tool in the design of functional foot orthoses.
Three clinicians with different levels of experience determined and classified the subtalar joint axis location, three times, on 52 individuals, using the clinical palpation, allocation and interpretation technique, as described by K. Kirby.
High intratester precision (ICC 0.72 to 0.93) was found for determining the axis location (SEM, 3.72° for angle/0.27 cm for X-axis); however, classification of the spatial position of the axis has large intertester variation (κ = 0.243 to 0.494)
The clinical palpation technique itself is reliable; the consistent attribution of a classification, in other words, interpretation, is weak. (J Am Podiatr Med Assoc 102(2): 122–129, 2012)