• 1.

    Kernozek, T, T Roehrs, and S McGarvey. :Analysis of plantar loading parameters pre and post surgical intervention for hallux vargus. .Clin Biomech (Bristol, Avon) 12::S18. ,1997. .

    • Crossref
    • PubMed
    • Search Google Scholar
    • Export Citation
  • 2.

    Huber, H and M Dutoit. :Dynamic foot-pressure measurement in the assessment of operatively treated clubfeet. .J Bone Joint Surg Am 86::1203. ,2004. .

  • 3.

    Thometz, JG, XC Liu, JC Tassone, et al. :Correlation of foot radiographs with foot function as analyzed by plantar pressure distribution. .J Pediatr Orthop 25::249. ,2005. .

    • Crossref
    • PubMed
    • Search Google Scholar
    • Export Citation
  • 4.

    Frykberg, RG, LA Lavery, H Pham, et al. :Role of neuropathy and high foot pressures in diabetic foot ulceration. .Diabetes Care 21::1714. ,1998. .

  • 5.

    Kong, PW and H De Heer. :Wearing the F-Scan mobile in-shoe pressure measurement system alters gait characteristics during running. .Gait Posture 29::143. ,2009. .

    • Crossref
    • PubMed
    • Web of Science
    • Search Google Scholar
    • Export Citation
  • 6.

    Hurkmans, HL, JB Bussmann, RW Selles, et al. :Validity of the Pedar Mobile system for vertical force measurement during a seven-hour period. .J Biomech 39::110. ,2006. .

    • Crossref
    • PubMed
    • Search Google Scholar
    • Export Citation
  • 7.

    Denegar, CR and DW Ball. :Assessing reliability and precision of measurement: an introduction to intraclass correlation and standard error of measurement. .J Sport Rehabil 2::35. ,1993. .

    • Crossref
    • PubMed
    • Search Google Scholar
    • Export Citation
  • 8.

    Shrout, PE and JL Fleiss. :Intraclass correlations: uses in assessing rater reliability. .Psychol Bull 86::420. ,1979. .

  • 9.

    Martinez-Nova, A, JC Cuevas Garcia, J Pascual Huerta, et al. :BioFoot in-shoe system: normal values and assessment of the reliability and repeatability. .The Foot 17::190. ,2007. .

    • Crossref
    • PubMed
    • Search Google Scholar
    • Export Citation
  • 10.

    Putti, AB, GP Arnold, L Cochrane, et al. :The Pedar in-shoe system: repeatability and normal pressure values. .Gait Posture 25::401. ,2007. .

    • Crossref
    • PubMed
    • Web of Science
    • Search Google Scholar
    • Export Citation
  • 11.

    Ramanathan, AK, P Kiran, GP Arnold, et al. :Repeatability of the Pedar-X in-shoe pressure measuring system. .Foot Ankle Surg 16::70. ,2010. .

Reliability and Repeatability of the Portable EPS-Platform Digital Pressure-Plate System

Ricardo Becerro de Bengoa Vallejo Escuela Universitaria de Enfermería, Fisioterapia, y Podología, Facultad de Medicina, Universidad Complutense de Madrid, Madrid, Spain.

Search for other papers by Ricardo Becerro de Bengoa Vallejo in
Current site
Google Scholar
PubMed
Close
 PhD
,
Marta Elena Losa Iglesias Facultad de Ciencias de la Salud, Universidad Rey Juan Carlos, Madrid, Spain.

Search for other papers by Marta Elena Losa Iglesias in
Current site
Google Scholar
PubMed
Close
 PhD
,
Joseph Zeni Science Docs Inc, Portland, OR.
Department of Physical Therapy, University of Delaware, Newark, DE.

Search for other papers by Joseph Zeni in
Current site
Google Scholar
PubMed
Close
 PhD, PT
, and
Stephen Thomas Science Docs Inc, Portland, OR.
McKay Orthopaedic Research Laboratory, University of Pennsylvania, Philadelphia, PA.

Search for other papers by Stephen Thomas in
Current site
Google Scholar
PubMed
Close
 PhD, ATC

Background:

Abnormal plantar pressures are the hallmark characteristic of several conditions and pathologic abnormalities. Pressure platforms allow for quick and accurate screening of patients and help guide clinical treatment. However, it is essential to evaluate the reliability and repeatability of these devices before making clinical decisions. The purpose of this study was to determine the reliability of the EPS-Platform during static and dynamic activities.

Methods:

Fifty-six healthy individuals stood and walked onto the pressure platform. Five trials were performed during two separate testing sessions to determine intrasession and intersession reliability. Pressure data were obtained and several variables of interest were calculated for intrasession and intersession reliability using intraclass correlation coefficients (ICCs), SEM, percent error, and coefficient of variation.

Results:

Static and dynamic intrasession and intersession reliability produced moderate-to-excellent ICCs, low SEMs, low percent errors, and low coefficients of variation. Static trials had higher ICCs, lower percent errors, and lower coefficients of variation compared with dynamic trials. Intersession reliability also had higher ICCs, lower percent errors, and lower coefficients of variation compared with intrasession reliability.

Conclusions:

This study demonstrates that the EPS-Platform is a reliable device for collecting gait plantar pressures. Static trials produce better reliability, most likely owing to the large inherent variability during dynamic gait. Intersession reliability was higher than intrasession reliability owing to the intersession measures being calculated with an average of five trials. By averaging the trials, the variability of gait is decreased, and this improves the accuracy of the results. These results can be used as the basis for future studies and to determine a priori sample sizes for investigations that use the EPS-Platform. (J Am Podiatr Med Assoc 103(3): 197–203, 2013)

Corresponding author: Marta Elena Losa Iglesias, PhD, Facultad de Ciencias de la Salud, Universidad Rey Juan Carlos, Avenida de Atenas s/n, Alcorcon, Madrid 28922, Spain. (E-mail: Marta.losa@urjc.es)
Save