Hicks JH: The foot as a support. .Acta Anat 25::35. ,1955. .
Lapidus WP: Kinesiology and mechanical anatomy of the tarsal joints. .Clin Orthop 30::20. ,1963. .
Huang CK, Kitaoka HB, An KN, et al: Biomechanical evaluation of longitudinal arch stability. .Foot Ankle 14::353. ,1993. .
Kitaoka HB, Luo ZP, An KN: Effect of plantar fasciotomy on stability of arch of foot. .Clin Orthop Relat Res 344::307. ,1997. .
Thordason DB, Hedman T, Lundquist D, et al: Effect of calcaneal osteotomy and plantar fasciotomy on arch configuration in a flatfoot model. .Foot Ankle Int 19::149. ,1998. .
Murphy GA, Pneumaticos SG, Kamaric E, et al: Biomechanical consequences of sequential plantar fascia release. .Foot Ankle Int 19::149. ,1998. .
Arangio GA, Chen C, Salathe EP: Effect of varying arch height with and without the plantar fascia on the mechanical properties of the foot. .Foot Ankle Int 19::705. ,1998. .
Gefen A: Stress analysis of the standing foot following surgical plantar fascia release. .J Biomech 35::629. ,2002. .
Cheung JTM, Zhang M, An KN: Effects of plantar fascia stiffness on the biomechanical responses of the ankle-foot complex. .Clin Biomech 19::839. ,2004. .
Riddle DL, Pulisic M, Pidcoe P, et al: Risk factors for plantar fasciitis: a matched case-control study. .J Bone Joint Surg Am 85::872. ,2003. .
Kirby KA: Foot and Lower Extremity Biomechanics: A Ten Year Collection of Precision Intricast Newsletters, Precision Intricast, Payson, AZ. ,1997. .
Erdemir A, Hamel AJ, Fauth AR, et al: Dynamic loading of the plantar aponeurosis in walking. .J Bone Joint Surg Am 86::546. ,2004. .
Ward ED, Smith KM, Cocheba JR, et al: In vivo forces in the plantar fascia during the stance phase of gait: sequential release of the plantar fascia. .JAPMA 93::429. ,2003. .
Carlson RE, Fleming LL, Hutton WG: The biomechanical relationship between the tendoachilles, plantar fascia and metatarsophalangeal joint dorsiflexion angle. .Foot Ankle Int 21::18. ,2000. .
Cheung JTM, Zhang M, An KN: Effect of Achilles tendon loading on plantar fascia tension in the standing foot. .Clin Biomech 21::194. ,2006. .
Cardinal E, Chhem RK, Beauregard CG, et al: Plantar fasciitis: sonographic evaluation. .Radiology 201::257. ,1996. .
Gibbon WW, Long G: Ultrasound of the plantar aponeurosis (fascia). .Skeletal Radiol 28::21. ,1999. .
Ozdemir H, Yilmaz E, Murat A, et al: Sonographic evaluation of plantar fasciitis and relation to body mass index. .Eur J Radiol 54::443. ,2005. .
Wall JR, Harkness MA, Crawford A: Ultrasound of plantar fasciitis. .Foot Ankle Int 14::465. ,1993. .
Akfirat M, Sen C, Gunes T: Ultrasonographic appearance of the plantar fasciitis. .J Clin Imaging 27::353. ,2003. .
Tsai WC, Chiu MF, Wang CL, et al: Ultrasound evaluation of plantar fasciitis. .Scand J Rheumatol 29::255. ,2000. .
Wearing SC, Smeathers JE, Yates B, et al: Sagittal movement of the medial longitudinal arch is unchanged in plantar fasciitis. .Med Sci Sports Exerc 36::1761. ,2004. .
Uzel M, Cetinus E, Ekerbicer C, et al: The influence of athletic activity on the plantar fascia in healthy young adults. .J Clin Ultrasound 34::17. ,2006. .
Pascual Huerta J, Alarcon Garcia JM: Effect of gender, age and anthropometric variables on plantar fascia thickness at different locations in asymptomatic subjects. .Eur J Radiol 62::449. ,2007. .
Huang YC, Wang LY, Wang HC, et al: The relationship between the flexible flatfoot and plantar fasciitis: ultrasonographic evaluation. .Chang Gung Med J 27::443. ,2004. .
Root ML, Orien WP, Weed JN: Biomechanical Examination of the Foot, Vol 1, Clinical Biomechanics Corp, Los Angeles. ,1971. .
Van Gheluwe B, Kirby KA, Roosen P, et al: Reliability and accuracy of biomechanical measures of the lower extremities. .JAPMA 92::317. ,2002. .
Hicks JH: The mechanics of the foot: II. The plantar aponeurosis and the arch. .J Anat 88::25. ,1954. .
Lemont H, Ammirati KM, Usen N: Plantar fasciitis: a degenerative process (fasciosis) without inflammation. .JAPMA 93::234. ,2003. .
Martin RL, McPoil TG: Reliability of ankle goniometric measurements: a literature review. .JAPMA 95::564. ,2005. .
Kilgour G, McNair P, Stott NS: Intrarater reliability of lower limb sagittal range-of-motion measures in children with spastic diplegia. .Dev Med Child Neurol 45::391. ,2003. .
Clapper MP, Wolf SL: Comparison of the reliability of the Orthoranger and the standard goniometer for assessing active lower extremity range of motion. .Phys Ther 68::214. ,1988. .
Elveru RA, Rothstein JM, Lamb RL: Goniometric reliability in a clinical setting: subtalar and ankle joint measurements. .Phys Ther 28::672. ,1988. .
Menadue C, Raymond J, Kilbreath SL, et al: Reliability of two goniometric methods of measuring active inversion and eversion range of motion at the ankle. .BMC Musculoskeletal Disord 7::60. ,2006. .
Smith-Oricchio K, Harris BA: Intrarrater reliability of subtalar neutral, calcaneal inversion and eversion. .J Orthop Sports Phys Ther 12::10. ,1990. .
Sell KE, Verity TM, Worrell TW, et al: Two measurement techniques for assessing subtalar joint position: a reliability study. .J Orthop Sports Phys Ther 19::162. ,1994. .
Background: We sought to investigate the thickness of plantar fascia, measured by means of ultrasonographic evaluation in healthy, asymptomatic subjects, and its relationship to body mass index, ankle joint dorsiflexion range of motion, and foot pronation in static stance.
Methods: One hundred two feet of 51 healthy volunteers were examined. Sonographic evaluation with a 10-MHz linear array transducer was performed 1 and 2 cm distal to its insertion. Physical examination was also performed to assess body mass index, ankle joint dorsiflexion, and degree of foot pronation in static stance. Both examinations were performed in a blinded manner.
Results: Body mass index showed moderate correlation with plantar fascia thickness at the 1- and 2-cm locations. Ankle dorsiflexion range of motion showed no correlation at either location. Foot pronation showed an inverse correlation with plantar fascia thickness at the 2-cm location and no correlation at the 1-cm location.
Conclusion: Body mass index and foot supination at the subtalar joint are related to increased thickness at the plantar fascia in healthy, asymptomatic subjects. Although the changes in thickness were small compared with those in patients with symptomatic plantar fasciitis, they could play a role in the mechanical properties of plantar fascia and in the development of plantar fasciitis. (J Am Podiatr Med Assoc 98(5): 379–385, 2008)